CircuitWerkes Sicon-8,
Recordable, Talking Remote Control
(with Internet Web Server & Setup/Control
software included)
Affordable power for
every facility
.
The
Sicon-8 is a modestly-priced, but
full-featured dial-up remote control
with speech capability and a powerful
new Webserver. The Sicon-8
can speak in your staff's language
because you record your own messages.
The Sicon-8 was designed to be a
complete solution for facilities with
basic to moderate control requirements.
All of the I/O, including 8 channels of
relays, are included on the main board
so there is no need to buy anything else
to use the product. All metering, status
and control connections are on
depluggable screw terminals. An expander
chassis, the SX-8, adds eight channels
of metering, status & control to an
existing Sicon-8. Up to three SX-8s may
be added to a Sicon-8 for a maximum of
32 channels.
Designed to be controlled from the
onboard Ethernet interface, any dial-up
telephone or its serial port, the
Sicon-8 gives you the control options
that you need. The onboard Web server
gives access to all of the Sicon-8's
metering, Status & basic control
functions & supports several
simultaneous users with 4 different
access levels. The Web server requires no
software other than a Javascript
(not Java) capable Web browser to
operate and works on multiple operating
systems and browsers. The dial-up
control is based on proprietary voice
recording technology that lets you
record your own messages, in any
language, and is smoother sounding than
most other voice recording technologies.
Choosing the right remote control for
your operation is a big decision. The
wrong choice can be expensive in many
ways. We've created a downloadable
comparison template that you can use to
compare our Sicon-8 to other brands. The PDF can be
downloaded here.
|
|
|
You've
been asking for years!
Now there is a new remote control
designed to fit your needs AND
your budget!
Features
|
>
|
Speaks every
language in the world because
you record your own messages.
|
>
|
Dial-up, site
controller with balanced audio
pass through and 8 channels of
metering, status and control.
Has up to 5 alarms per channel.
|
>
|
Optional
8-channel expansion module gives
you up to 32 total channels.
|
>
|
All connections
are on depluggable screw
terminals right on the main
chassis. No additional panels
are needed for operation.
|
>
|
Free Windows
interface program with
multi-site capability lets you
setup or monitor/log the Sicon-8
(but is not required for
standard operation).
|
>
|
Basic time of
day/date automation (event
scheduler) functions are
built-in. |
>
|
Web
Server/Ethernet interface lets
you control the Sicon-8 over
your network or the Internet.
|
>
|
When
controlling via Webserver, the
applet or Sicontroller software
alerts you if the network fails
& tries to auto-reconnect.
|
>
|
Supports
simultaneous users from
telephone, Web & serial /
USB. All control & metering
functions are available to
everyone. The Webserver also
supports up to 10 simultaneous
users by itself. |
>
|
Cell phone
audio interface lets you use the
Sicon-8 with any auto-answer
wireless phone. Great for sites
with no phone service!
|
>
|
Front panel
programming port lets you
program the Sicon-8 without a
computer
or telephone line.
|
>
|
Telephone
interface, voice codec,
Webserver & all
relays are on easily replaced
daughter boards. |
>
|
Uses
heavy 5 Amp, SPDT relays on
channels 1-6 for maximum
flexibility. |
>
|
1 Amp,
DPDT relays on channels 7 &
8 can be programmed for latching
or momentary. |
>
|
Pre-programmed
for English (Spanish on request)
& is easily re-recorded.
|
|
A detailed PDF datasheet for the Sicon-8 can
be downloaded here.
Click
here to get the manual (PDF)
|
Below: The Sicontroller remote interface software (main
display)
Click here or on the picture of
the software for more info about the FREE software
interface for the Sicon-8
The Sicon-8 software can
connect to your Sicon-8 via serial port, Web server or
modem. Multi-site capability
lets you monitor multiple sites from a central location.
Software also makes setup a snap, but the Sicon-8 is
fully functional even without the software.
The
Sicon-8's Onboard Web-server:
The onboard Web server duplicates much of the
Sicontroller software's control functions and runs
on any Java capable browser.
As shown below, the Web server is designed to be
uncomplicated and will run on multiple platforms
and browsers, provided that
they are Java capable. It even works on the
iPhone's Safari browser. Meters are updated
approximately every two seconds and
the Web server shows the current meter values,
channel status and alarms.
|
The
Sicon-8's Web server allows for 4 different access
levels:
Reader - Can not operate any controls. All
controls are hidden from readers.
Controller - Can operate any control on the main
page but cannot perform or access any setup
functions
Administrator - Has access to all functions,
except top level password changes.
Super-Administrator - Similar to the
administrator, the Super-Admin is the only one
that can change their own password.
This user level is designed to protect owners from
being locked out of the Sicon-8.
The Sicon-8's internal Webserver can send
email/text messages for alarms and routine
logging.
Hardware logs can be emailed at scheduled
intervals or can be viewed online at any time.
The Webserver has its own alarm handler, with
advanced new features, and can perform
action sequences independently from the main
Sicon-8.
Checks its timekeeping against NTP servers and can
automatically adjust the real-time clock.
|
|